Septic Systems Installation
Guidelines for designing proper performing OSSFs:
1.Flow equalization for all ATU's
2.Pressurized time dosing to field for systems with primary treatment only
3.Homeowner questionnaire
a.No ATU's if not perpetually occupied
4.Use TCEQ flows to establish average daily flows only
a.Use a project-specific peak flow multiplier for design
5.Do not depend on homeowner for success of system.
a.Automatic zone switching
i.verifiable
b.Automatic filter flushing
c.Automatic field flushing
d.Chlorine disinfection only if provider supplying Cl2 monthly
i.Ozone or UV disinfection, otherwise
e.Flow meter to verify system performance and usage
6.Electronic monitoring, if used, must verify system performance between visits
a.Auditable reporting
b.Verify communication integrity, at least monthly
c.Show system performance
i.Historical, at a minimum
ii.Real Time, for commercial
d.Service Provider's performance tracking
7.Commercial/Institutional Pretreatment Required
a.Determine wastewater characteristics
i.Influent
1.BOD, TSS, pH, COD, FOG, Temperature, Toxicity
2.Multiple samples
3.Multiple days
ii.Effluent
1.BOD >140
2.TSS >140
3.FOG > 10
4.pH = 7.0 approx.
b.Determine flows
i.GPM, avg
ii.GPM, peak
iii.GPD, avg
iv.GPD, peak
c.Determine balance of design using steps 1-5.
Previous Article : Septic System Pumps - - Next Article : Residential Septic System
-
Providing Quality Service...Guaranteed In the Greater Austin Area of Travis, Hays, Williamson, Burnet, & Bastrop Counties
, Onion Creek, Windmere, The Hills, Hays County, Dripping Springs, Buda, Jarrell, Georgetown, Brushy Creek, Bell County, Misc Locations.
Call (512) 338-1804 for fast, dependable service.
-
Aerobic System Pumping Aerobic Treatment Units (ATU) generally require more frequent pumping than do septic tanks of comparable size. There are 2 reasons: The...
-
Improved Efficiency - Public And Private (Rare story: A public agency and private company work together to improve efficiency for themselves AND their customers.) Background: Since the State-wide change in...
-
Seller Says "Too Bad" Seller Says “Too Bad” After Homebuyers Find Rotting Septic Tank Under Plywood (From Pumper Magazine, October 23, 2018) A news organization in Cortland Manor,...
-
Septic Tank Lid Each compartment of a septic tank has an access port which is sealed with a lid. These...
-
Septic Treatment With increasing frequency, people are asking how to use NSF-listed home plants for office, restaurant, or other non-residential...
-
Service Contract Aren't you tired of all these renewal reminders?You are probably getting tired of receiving all these reminders plus...
-
Field Leach Septic System There are three reasons why septic system maintenance is important to you and your community. 1.The first is...
-
Septic Tank Filter Tank maintenance and septic filter & system installations should always be performed by licensed and insured professional. ...